REFRIGERATION, CONDITIONING SYSTEM
Unit). To ensure keeping the heat on pipes, prevent dew condensation, copper pipes need to be insulated from external heat. NANOFLEX insulation is applied for refrigerating systems to control condensation problems, also to reduce waste of energy by higher heat gain into the cooling systems of air conditional. NANOFLEX insulation has been widely used in […]
Unit). To ensure keeping the heat on pipes, prevent dew condensation, copper pipes need to be insulated from external heat.
NANOFLEX insulation is applied for refrigerating systems to control condensation problems, also to reduce waste of energy by higher heat gain into the cooling systems of air conditional. NANOFLEX insulation has been widely used in refrigerating system due to the following superior characteristics:
- Closed cell structure. Non-polar polymer bases with high water and moisture resistance
- Low and stable thermal conductivity value.
- Comply with almost international smoke and flammability standards.
- Gives the finished insulation a neat aesthetic appearance. No coating is needed on most indoor usage.
- Easy of installation, cutting and shaping immediately at construction site, no dust can influence people installation and advanced life environment quality.
Typical for Refrigeration Systems.
Recommended thickness (mm) of NANOFLEX insulation for refrigeration.
Ambient Temperature |
260C |
280C |
300C |
350C |
||||||||||||||||
Relative Humidity |
65% |
70% |
75% |
80% |
85% |
90% |
65% |
70% |
75% |
80% |
85% |
90% |
75% |
80% |
85% |
90% |
75% |
80% |
85% |
90% |
Refrigeration to 00C (For Air Conditional Wall) – R22 |
||||||||||||||||||||
Pipe up to 35mm O.D |
13 |
13 |
19 |
19 |
32 |
32 |
13 |
15 |
19 |
19 |
32 |
38 |
19 |
25 |
32 |
38 |
19 |
25 |
32 |
44 |
Pipe 42-60mm O.D |
13 |
13 |
19 |
25 |
32 |
38 |
15 |
15 |
19 |
25 |
32 |
38 |
19 |
25 |
32 |
44 |
25 |
32 |
38 |
50 |
Pipe up to 67-140mm O.D |
13 |
19 |
19 |
25 |
38 |
44 |
15 |
19 |
19 |
25 |
38 |
44 |
25 |
32 |
38 |
50 |
25 |
32 |
38 |
57 |
Pipe above 140mm O.D |
13 |
19 |
25 |
32 |
38 |
50 |
15 |
19 |
25 |
32 |
38 |
50 |
25 |
32 |
38 |
57 |
25 |
32 |
50 |
70 |
Refrigeration to 00C (For Air Conditional Wall) – R401A |
||||||||||||||||||||
Pipe up to 35mm O.D |
19 |
19 |
19 |
19 |
32 |
38 |
19 |
19 |
19 |
25 |
38 |
44 |
25 |
32 |
38 |
50 |
25 |
32 |
38 |
57 |
Pipe 42-60mm O.D |
19 |
19 |
19 |
19 |
38 |
44 |
19 |
19 |
25 |
32 |
38 |
50 |
25 |
32 |
38 |
57 |
32 |
32 |
50 |
64 |
Pipe 67-140mm O.D |
19 |
25 |
19 |
25 |
44 |
50 |
19 |
25 |
32 |
32 |
50 |
57 |
32 |
38 |
50 |
64 |
32 |
38 |
50 |
76 |
Pipe above 140mm O.D |
19 |
25 |
19 |
25 |
50 |
57 |
19 |
25 |
32 |
38 |
50 |
64 |
32 |
38 |
50 |
76 |
32 |
44 |
57 |
88 |